Criteria of diastolic(volume) overloading LVH
I. Voltage Criteria
- Limb leads
- Lead I: R > 15 mm or R > 18 mm with left axis deviation (LAD)
- Lead aVL: R > 12 mm or R > 16 mm with LAD
- Lead II or III: R > 25 mm
- Precordial leads
- V5 > 26 mm
- Sum of S wave in V2 and R wave in V5 > 36 mm
- V6 > V5
- Orthogonal leads
- Transverse plane mean QRS vector > 20
- Frontal plane mean QRS vector > 25
II. Tall, peaked T-waves in leads I, aVL, V5, and V6
III. Increased QRS duration
- Instrinsicoid deflection > .09 sec.
- Deep Q-waves in leads I, aVL, V5, and V6
IV. P-wave abnormality of left atrial enlargement (LAE)
Scroll back up to show EKG